Two ways to connect
There are two ways to connect the internal wiring of
the harting. You see two tables and drawing in outlines. There is the so
called 'Dutch norm', introduced by Flashlight / NOB, this is the standard
way in the Netherlands. (see table 1 / figure 1) And you have the DIN standard,
like is used in Europe. (see table 2 / figure 2). We deliver for customers
in the Netherlands the harting wired like the 'Dutch norm' and for customers
from abroad we deliver the harting wired according the DIN standard.
If you like your harting wired in another way, you can let us know in advance (when you order), or you can change it yourself according to the following directions.
Table 1 'Dutch norm' pin assignment 'harting'-type connector
Dimmer nr. | Connector pin | ||
1
2 3 4 5 6 |
7*
8* 9* 10* 11* 12* |
1 /phase L3
3 /phase L3 5 /phase L2 7 /phase L2 9 /phase L1 11 /phase L1 |
2 /neutral
4 /neutral 6 /neutral 8 /neutral 10 /neutral 12 /neutral |
Dimmer nr. | Connector pin | ||
1
2 3 4 5 6 |
7*
8* 9* 10* 11* 12* |
1 /phase L3
2 /phase L3 3 /phase L2 4 /phase L2 5 /phase L1 6 /phase L1 |
9 /neutral
10 /neutral 11 /neutral 12 /neutral 13 /neutral 14 /neutral |
Figure 1 Neutral connection 'Dutch norm' | Figure 2 Neutral connection DIN standard |
![]() |
![]() |
How to change the internal wiring of the harting-connector
from 'Dutch norm' to DIN standard
1. DISCONNECT THE MAINS: DANGEROUS TO LIFE !!!
2. unscrew at dimmer outside the harting-connector-body
3. remove the bridge completely
4. connect the wires one by one as follows:
· 1 stays 1
· 3 becomes 2
· 5 becomes 3
· 7 becomes 4
· 9 becomes 5
· 11 becomes 6
5. bow the bridge so that the feet are in line. Srew
the bridge on contact 9 t/m 16
6. screw the harting-connector-body back on the dimmer
Change the harting at both sides of the dimmer. If you
have any questions, let us know.